{"product_id":"half-bridge-with-over-current-protection-400v-1a","title":"Half-Bridge with Over Current Protection – 400V\/1A","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHalf-Bridge Driver\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproject presented here is designed to support load power supplies of up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e400V DC\u003c\/strong\u003e. The board features the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIRS2890DS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHalf-Bridge Gate Driver IC, which is paired with two IGBTs rated at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8A\/650V\u003c\/strong\u003e, conveniently mounted on the board. The board features overcurrent shutdown. Barrier Terminal Blocks provided for load and input supply.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoad Power Supply 400V DC\u003c\/li\u003e\n\u003cli\u003eMaximum Load 1Amps\u003c\/li\u003e\n\u003cli\u003eLogic Gate Driver Power Supply 15V-16V DC (VC\/VCC)\u003c\/li\u003e\n\u003cli\u003eFault Clear\/Enable Power Supply 3.3V-5V (VD)\u003c\/li\u003e\n\u003cli\u003eFault Clear Time Approx. 1mS\u003c\/li\u003e\n\u003cli\u003eOver Current Protection Threshold 4.58A (I-TRIP)\u003c\/li\u003e\n\u003cli\u003eShort Circuit Time Constant 1-2uS\u003c\/li\u003e\n\u003cli\u003eHIN\/LIN Input Signal ,3.3 V, 5 V, and 15 V Logic-compatible\u003c\/li\u003e\n\u003cli\u003eOvercurrent Protection, Fault Reporting and Enable\u003c\/li\u003e\n\u003cli\u003eBarrier Terminal Blocks for Power and Load\u003c\/li\u003e\n\u003cli\u003eHeader Connector for Gate Driver Supply, Inputs, RFE and VD 3.3-5V\u003c\/li\u003e\n\u003cli\u003e4 x 4 mm PCB Mounting Holes\u003c\/li\u003e\n\u003cli\u003ePCB Dimensions 60.01 x 34.93 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFunctions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOvercurrent shutdown\u003c\/li\u003e\n\u003cli\u003eUndervoltage lockout for both high-side and low-side\u003c\/li\u003e\n\u003cli\u003eCross-conduction prevention\u003c\/li\u003e\n\u003cli\u003eAll switches turn off during protection\u003c\/li\u003e\n\u003cli\u003eActive-high input signal logic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLoad Handling and Overcurrent Protection\u003c\/h3\u003e\n\u003cp\u003eThe board is capable of handling loads of up to 1Amp, making it suitable for a variety of applications. The overcurrent trip point is set to 4.58A, providing an added layer of protection against overcurrent conditions. In the event of a fault, the board is designed to clear the condition within 1ms, minimizing downtime and ensuring rapid recovery.\u003c\/p\u003e\n\u003ch3\u003eConfiguring the Board for Custom MOSFET\/IGBT Applications\u003c\/h3\u003e\n\u003cp\u003eThe board can be tailored to meet specific user requirements for switching frequency, DC bus voltage and current. The gate driver chip is designed to drive either IGBT or MOSFET, with provisions for using TO263\/D2PK MOSFET\/IGBT components. To ensure optimal performance, it is crucial to select a MOSFET\/IGBT that matches the output current capacity of the chip, which has a current sink\/source capacity of 220mA\/480mA. Key Considerations for Configuring the Board with an Alternative MOSFET\/IGBT, following factors must be taken into account: Bootstrap Capacitor Value: This value is dependent on the operating frequency and should be selected accordingly. Gate Resistors and Diodes (R2, R3, R4, R6, D1, D2): D1 and D2 are 1N4148-type diodes, and all resistors are 0805 size. These components should be chosen based on the specific requirements of the MOSFET\/IGBT being used. DC Bus Capacitors (C3, C4): The value and voltage of these capacitors must be carefully selected to ensure reliable operation. Shunt Resistor Value for Over Current Protection: This value is critical for protecting the board from overcurrent conditions and should be chosen based on the specific requirements of the application. Time Constant (R7 and C8): The default time constant is set to 1-2μs for overcurrent shutdown. This value can be adjusted as needed to suit the specific application. Fault Clear Time (R5 and C7): This value determines the time it takes for the board to clear a fault condition and should be chosen based on the specific requirements of the application.\u003c\/p\u003e\n\u003ch3\u003eOver Current Protection\u003c\/h3\u003e\n\u003cp\u003eThe integrated comparator is triggered, if the voltage VITRIP is higher than 0.5 V. In case of a trigger event, the voltage at pin RFE is pulled down to low. The IRS2890DS has an overcurrent shutdown function. Its internal comparator monitors the voltage of the ITRIP pin, and if this voltage exceeds the VITRIP+, which is specified in the device’s datasheets, a fault signal is activated and all channels are turned off. Typically, the maximum short-circuit current magnitude is gate voltage dependant. A higher gate voltage results in a larger short-circuit current.\u003c\/p\u003e\n\u003ch3\u003eFault output, Fault clear timer and Enable pin\u003c\/h3\u003e\n\u003cp\u003eThis is the fault output alarm pin. An active low output is given on this pin for a fault-state condition in the IRS2890DS. The alarm conditions are overcurrent detection and low-side bias UV (undervoltage) operation. The RFE output is open-drain configured. The RFE signal line is pulled up to the logic power supply (5 V or 3.3 V) with resistance R5 and capacitor C7 between RFE and COM pins to program fault clear time. Externally pulling down the pin can disable the output; for normal operation, this pin default pulled up.\u003c\/p\u003e\n\u003ch3\u003eFault output circuit and fault-clear time setup\u003c\/h3\u003e\n\u003cp\u003eThe IRS2890DS provides adjustable fault-clear timer. Once ITRIP pin recognizes a fault, the RFE pin is internally pulled to COM. The RFE output stays in the low state until the fault condition has been removed and the fault clear timer expires; once the fault-clear timer expires, the voltage on the RFE pin will return to its external pull up voltage.  The length of the fault-clear time period (TFLTCLR) is determined by the exponential charging characteristics of the capacitor, where the time constant is set by R5 and C7. The length of the fault-clear time period is approx. 1mS. User may refer data sheet of the chip for more information to change the fault clear time.\u003c\/p\u003e\n\u003ch3\u003eEnable input circuit\u003c\/h3\u003e\n\u003cp\u003eIRS2890DS provides an enable functionality that allows it to shut down or enable the output. When the RFE pin is externally pulled up, the HVIC is able to operate normally (assuming no other fault conditions: undervoltage protection of VCC or overcurrent protection of ITRIP). When the RFE pin is pulled down externally, the gate drive outputs are pulled low until the enable condition is restored.\u003c\/p\u003e\n\u003ch3\u003eInput Signal\u003c\/h3\u003e\n\u003cp\u003eThe input signals are active-high configured. There is an internal pull-down resistor from each input signal line to COM.\u003c\/p\u003e\n\u003ch3\u003eOperating Frequency \u0026amp; Test\u003c\/h3\u003e\n\u003cp\u003eTest is conducted with 6.5Khz input frequency, board can support frequency up to 20Khz. Resistor used as load to conduct the test.\u003c\/p\u003e\n\u003ch3\u003eUndervoltage protection\u003c\/h3\u003e\n\u003cp\u003eThis IC provides undervoltage lockout protection on both the VCC (logic and low-side circuitry) power supply and the VBS (high-side circuitry) power supply.\u003c\/p\u003e\n\u003ch3\u003eHigh Voltage Warning\u003c\/h3\u003e\n\u003cp\u003eIt is important to note that the project operates with lethal voltage, and users must take all necessary safety precautions before testing the board. After the power is off, the DC bus capacitors remain charged and have lethal voltage, requiring an appropriate waiting time for capacitor discharge before conducting tests.\u003c\/p\u003e\n\u003ch3\u003eGate Driver Chip Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFloating channel designed for bootstrap operation\u003c\/li\u003e\n\u003cli\u003eFully operational to +600 V\u003c\/li\u003e\n\u003cli\u003eTolerant to negative transient voltage, dV\/dt immune\u003c\/li\u003e\n\u003cli\u003eGate drive supply range from 10 V to 20 V\u003c\/li\u003e\n\u003cli\u003eUndervoltage lockout for both channels\u003c\/li\u003e\n\u003cli\u003e3 V, 5 V, and 15 V input logic-compatible\u003c\/li\u003e\n\u003cli\u003eMatched propagation delay for both channels\u003c\/li\u003e\n\u003cli\u003eLower di\/dt gate driver for better noise immunity\u003c\/li\u003e\n\u003cli\u003eOutputs in phase with inputs\u003c\/li\u003e\n\u003cli\u003eIntegrated bootstrap FET\u003c\/li\u003e\n\u003cli\u003eSuitable for both trapezoidal and sinusoidal motor control\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection, fault reporting and enable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnections\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCN1 Power Input: Pin1 = Load Power Supply 400V DC, Pin 2 = GND\u003c\/li\u003e\n\u003cli\u003eCN2: Pin 1 = VCC 12V-15V DC, Pin 2 High Input, Pin 3 = Low Input, Pin 4 = RE\/Fault, Pin 5 = GND, Pin 6 = 3.3V-5V DC\u003c\/li\u003e\n\u003cli\u003eCN3 Load: Pin 1 = GND, Pin2 = Output\u003c\/li\u003e\n\u003cli\u003eD3: Power LED\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"dotfry","offers":[{"title":"Default Title","offer_id":47242803118252,"sku":null,"price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/6436\/7532\/files\/B145.jpg?v=1789735698","url":"https:\/\/dotfry.com\/products\/half-bridge-with-over-current-protection-400v-1a","provider":"dotfry","version":"1.0","type":"link"}